Disproportionality Analysis
Does this pair stand out?
In one sentence
Disproportionality analysis flags medicine and event pairs reported more often than the rest of a safety database would lead you to expect.
The flag is a prompt to look, called a signal of disproportionate reporting (SDR), not proof of harm. EudraVigilance, run by the European Medicines Agency (EMA), uses the reporting odds ratio (ROR).
Think of it like this
A smoke alarm does not know what is burning. Toast and a house fire sound the same. All it tells you is to go and look.
Key insights
A reporting odds ratio of 3 on three reports is not flagged; the same ratio on five is. With few reports the lower bound falls far below the ratio. Chapter 1.
A flag may come from confounding, reporting habits or coding. It becomes a validated signal only when someone has read the cases and found enough evidence to justify further analysis. Chapter 2.
In the research behind the EudraVigilance rules, the choice of statistic hardly changed performance. The thresholds did, and the case count is the one to raise. Chapter 3.
In EudraVigilance these methods found about half of adverse reactions before other methods did. So a pair also reaches review through a short list of designated events, or a fatal case, with no ratio at all. Chapter 3.
Jump to: 1 The four boxes 2 What a flag says 3 Formula or threshold 4 Test yourself
Chapter 1
How many reports does a ratio of 3 need?
Every report falls into one of four boxes: does it name the medicine, and does it name the event? Click through the counts as reports arrive. The ratio stays close to 3, so watch the interval.
Click a number: reports naming both the medicine and the event
Click one: on the additional monitoring list?
| Names the event | Does not | |
|---|---|---|
| This medicine | a23451015 | b1320273367100 |
| All other medicines | c5,000 | d100,000 |
(a ÷ b) ÷ (c ÷ d) is the reporting odds ratio
The ratio looks high, but two reports say little: the interval runs across 1, and two is below either minimum.
A ratio of exactly 3, and the interval still crosses 1. The bound fails, whichever medicine this is.
The bound just clears 1. Now the list decides: four reports meet the minimum of 3 under additional monitoring, but not the 5 for any other medicine.
One more report, and both minimums are met. The ratio has hardly moved since the first stop.
Twice the reports, the same ratio, a tighter interval. It still says nothing about cause.
The European Medicines Agency’s own worked example: 15 reports against 100, a ratio of 3.
3.083.002.963.032.993.00reporting odds ratio
95% interval: 0.69 to 13.640.89 to 10.101.04 to 8.471.18 to 7.771.54 to 5.811.74 to 5.17
- Lower bound above 1MetNot met
- At least 5 reportsAt least 3 reportsMetNot met
Not flagged yetFlagged for review
Illustrative counts, except 15 against 100, the guide’s own example. Tests as published in 2016; a third is assumed met: the event is on the Important Medical Event list.
The lower bound is not a significance test, the agency says: it is a practical way to show how little a few reports can support.
Chapter 2
What does a flag actually tell you?
It speaks about reports, not patients. The database does not know how many people took the medicine.
Guess first
A pair comes back with a reporting odds ratio of 6. What does that number say?
You got it.Not quite.Reports of this event are six times as likely, in odds, among this medicine’s reports as among all others. Neither the agency nor the United States (US) Food and Drug Administration (FDA) reads it as a rate or a risk.
this statistical association may reflect, but does not imply, a causal relationship
EudraVigilance screening guide, section 4.1.1
Confounding, reporting artefacts and coding practices can raise a ratio with no harm behind it. The United States (US) Food and Drug Administration (FDA) adds media publicity, litigation and a product being newly marketed. A real effect can also be masked.
So a flag opens a review of the product information, the data, the case reports and other evidence, and it may stop at any step.
14,555monitoring reports in 2025, for 2,799 substances. The agency reviewed 1,201 potential signals in detail; 60 confirmed signals reached its Pharmacovigilance Risk Assessment Committee. Different scopes, so not a strict funnel.
Don’t confuse it with: a validated signal
A statistical flag
Signal of disproportionate reporting
- Who decides: the rules, automatically
- Means: this pair deserves a look
A validated signal
Signal management
- Who decides: an assessor, weighing strength, clinical relevance and previous awareness
- Means: enough evidence of a potentially causal association to analyse further
The Council for International Organizations of Medical Sciences proposed calling the first a “statistic” of disproportionate reporting. The agency kept the old name.
Chapter 3
Does the choice of formula matter?
Less than you might expect. Pharmacoepidemiological Research on Outcomes of Therapeutics by a European Consortium (PROTECT), the project behind the rules, compared five statistics: performance depended largely on the thresholds.
| EudraVigilance, European Union | FDA, US | |
|---|---|---|
| Statistic | Reporting odds ratio, which replaced the proportional reporting ratio | Empirical Bayes Geometric Mean, built on the proportional reporting ratio |
| Few reports | Lower bound of the 95% interval, plus a minimum count | Bayesian shrinkage pulls small counts toward no effect |
| Cut-off | Bound above 1, at least 3 or 5 cases, event on the Important Medical Event list | No single figure in the 2018 paper: adjusted for severity, so a cancer drug and an acne drug differ |
Raise the count, not the ratio. A bound set above 1 risks missing a reaction with a modest risk. In PROTECT, five cases instead of three removed 35% of false positives and 9% of true ones, with a median delay of eight months.
Statistics are one route to review. A pair is also highlighted if it is a Designated Medical Event, where one report may be enough, or a fatal case of an Important Medical Event.
Who screens? The agency and national authorities and, since August 2025, every marketing authorisation holder, at a frequency proportionate to risk, under Implementing Regulation (EU) 2025/1466.
The formulas and the fine print
- Reporting odds ratio: (a / b) / (c / d). 95% interval: the ratio divided and multiplied by exp(1.96 s), where s is the square root of 1/a + 1/b + 1/c + 1/d. If c is 0 the ratio cannot be computed, and EudraVigilance sets it to 99.9 to mark a possible flag.
- Why the European Union switched: the reporting odds ratio is as simple as the proportional reporting ratio, performs the same and is a better base for later models.
- Proportional reporting ratio: [a / (a + b)] / [c / (c + d)]. For this ratio the product’s own reports do not feed the expected count; for the Empirical Bayes Geometric Mean, produced by the Multi-Item Gamma Poisson Shrinker, they do. Its lower 90% limit is called EB05.
- The minimum of 3 applies to active substances on the additional monitoring list, unless the only reason for listing is a requested post-authorisation safety study. Flags grow less reliable as a medicine ages, which supports a lower count for new medicines.
- The guideline: Module IX of Good Pharmacovigilance Practices, due for an update in the second quarter of 2026, still showed its 2017 revision on 3 November 2026.
- Earlier work on the same question in EudraVigilance found 25% fewer false positives, 12% fewer reactions detected early and a one-month delay; the guide explains the gap by the different reference standard.
- Other rules in the 2016 comparison (as listed by the agency, not checked against current practice): Uppsala Monitoring Centre, lower 95% bound of the Information Component above 0; the Medicines and Healthcare products Regulatory Agency, EB05 at least 1.8, at least 3 cases, Empirical Bayes Geometric Mean at least 2.5.
- Subgroups by age or region improved sensitivity and precision in large international databases, not necessarily in small ones.
- The system: a new signal detection system went live at the agency in December 2025 and generates the monitoring reports. The annual report does not say the thresholds changed; the criteria above date from the 2016 guide.
Chapter 4
Test yourself
Myth or Truth? Pick an answer to see the explanation.
“A high reporting odds ratio proves the medicine causes the reaction.”
The association is statistical. Confounding, publicity or coding habits can raise a ratio, and neither the agency nor the FDA reads it as cause.
“To cut false alarms, raising the minimum case count works better than raising the ratio threshold.”
Module IX Addendum I says so directly. A bound set above 1 risks missing reactions with a modest risk.
“A pair must show disproportionate reporting before anyone reviews it.”
A Designated Medical Event or a fatal case of an Important Medical Event is highlighted without it. One report of Stevens-Johnson syndrome with a new medicine should prompt a look.
Sources (8)
- European Medicines Agency: Screening for adverse reactions in EudraVigilance, EMA/849944/2016, 19 December 2016 (PDF)
- Good Pharmacovigilance Practices, Module IX Addendum I: Methodological aspects of signal detection, in effect 22 November 2017 (PDF)
- Good Pharmacovigilance Practices, Module IX: Signal management, Rev 1, 9 October 2017 (PDF)
- European Medicines Agency: Good pharmacovigilance practices, list of modules (checked 3 November 2026)
- European Medicines Agency: Signal management (checked 3 November 2026)
- European Medicines Agency: Questions and answers on Implementing Regulation (EU) 2025/1466, Rev. 2, 28 January 2026 (PDF)
- European Medicines Agency: 2025 Annual Report on EudraVigilance, 12 March 2026 (PDF)
- US Food and Drug Administration: Data Mining at FDA, white paper, content current as of 20 August 2018
Last reviewed against these 8 sources. Every page is reviewed at least every six months.